BT/Power Equipment-Rectifier, Inverter and UPS/2022 Bhutan Telecom Ltd Contract Awarded
Procurement Category: Goods
Dzongkhag/Location: Thimphu
Goods/Services/Work Type: Retail Trade/Hardware/Electricals
Procurement Method: Open Tendering
Annual Procurement Plan: 2022
Bidding Process: Single Stage Bidding - Single Envelope
Contact Details: manager.powerandinfra@bt.bt/procurement@bt.bt
Status: Contract Awarded
Bidding Details
Submission Date: January 31 2023, 11:00 AM
Opening Date: January 31 2023, 02:00 PM
Prebid Date: None
Prebid Place: None
Earnest Money Deposit Details
EMD Type: Percent
EMD Value: 2.0%
Evaluation Details
Financial Evaluation: 100%
Agency Documents
Sl | Document | Link |
---|---|---|
1 | Integrity Pact Document | Download |
2 | RFP | Download |
Document Prerequisites For Participation
Sl | Document |
---|---|
1 | Catalogue/DataSheet |
2 | Integrity Pact Document |
3 | OEM Certificate |
4 | Other Document |
5 | Tax Clearance |
6 | Trade License |
Tender Items(BOQ/BOM)
Sl | Item Code | Item Name, Additional Description/Specifications |
UoM | Qty |
---|---|---|---|---|
1 | FA00602 | SMPS Rectifier Battery Charger, IP Vac = 180 – 280 Vac; OP = (-48V DC), 500 Amps, Modular Type with minimum 8 No of Modules and 8 slots of 60 Amps per module. Must have load facility to connect both critical and non critical loads using appropriate MCBs and HRC Fuse. Also should have an inbuilt controller having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP. ( Vertiv/Delta / benning/Dynamic Power/Exicom), | Set | 22.0 |
2 | FA00829 | Solar-DG-Utility-Battery Hybrid MPPT system, modular type, 2 kW, 500 Amps, having min 6 (Five) solar mppt modules of 40 Amps capacity and 2 additional MPPT slots . 6 nos of rectifier module of capacity 80 amps and 2 additional rectifier slots having the following features: Must have load facility to connect both critical and non critical loads using appropriate MCBs and HRC Fuse. Further, the system also should have min two nos of appropriate rating of HRC fuses for connecting of min two battery banks of min 450 Ah per bank. Also should have an inbuilt controller having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP: 1. Solar Converter Specs: Input voltage (DC), Vertiv/Delta/Eltek/Dynamic Power/Exicom, | Set | 27.0 |
3 | FA00896 | SMPS Rectifier Battery Charger, IP Vac = 3 phase, 4 Wire; OP = (-48V DC), 2500 Amps, Modular Type with minimum 30 No of Modules and 30 slots of 60/80 Amps per module. Must have load facility to connect both critical and non critical loads using appropriate MCBs and HRC Fuse. Also should have an inbuilt controller having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP. Make: (Vertiv/Delta / benning/Dynamic Power), | Set | 1.0 |
4 | FA00560 | Rectifier Module R48-4000e, | no | 8 |
5 | FA00559 | Rectifier Module R48-3200, | no | 8 |
6 | FA00561 | Rectifier MPPT Modules S48-3000, | no | 12 |
7 | FA00390 | Inverter (3KVA), Rackmount, Input Voltage :44-55V DC, Output : 230V AC, | nos | 20.0 |
8 | FA00391 | Inverter ( 5KVA), Rackmount, Input Voltage: 44-55 VDC, OutPut:230V AC, | no | 12 |
9 | FA00898 | UPS: Double conversion on line UPS with external batteries 5kVA, 230 V AC Make: Delta/Vertiv/APC/Schneider , | no | 1 |